60W Waterproof Single Output Switching Power Supply LPV-60 series

Get the waterproof and durable {60W Waterproof Single Output Switching Power Supply LPV-60 series} from our factory. Trust our quality and expertise in power supply manufacturing.

Request a Quote
  • 60W Waterproof Single Output Switching Power Supply LPV-60 series
  • 60W Waterproof Single Output Switching Power Supply LPV-60 series
  • 60W Waterproof Single Output Switching Power Supply LPV-60 series
  • 60W Waterproof Single Output Switching Power Supply LPV-60 series
  • 60W Waterproof Single Output Switching Power Supply LPV-60 series
  • 60W Waterproof Single Output Switching Power Supply LPV-60 series
  • 60W Waterproof Single Output Switching Power Supply LPV-60 series

PRODUCTS DETAILS

1. The input voltage of the waterproof switching power supply should be selected according to the design of the circuit. Generally, there are two kinds of input voltage: 220 volts and 110 volts. If you choose improperly, it will damage the switching power supply. 2. Do not connect the ground wire and neutral wire end of the output voltage wiring wrongly, and make sure that the grounding is reliable. 3. After the switching power supply is installed, it is necessary to conduct a power-on trial operation, check the condition of each part, and ensure that it can be powered on after it is normal.60W Waterproof Single Output Switching Power Supply LPV-60 series Constant voltage design Universal AC input/Full range Withstand 300VAC surge input for 5 seconds Protections: short circuit/ over load/ over voltage Cooling by free air convection Small and compact size Fully encapsulated with IP67 level Fully isolated plastic case Class II power unit, no FG Class 2 power unit Pass LPS Suitable for LED lighting and moving sign applications 100% full load burn-in test Low cost, high reliability 2 year warranty

Note on the use of waterproof power supply

Specifications

SPECIFICATIONS
OUTPUT  
Model

LPV-60-5

LPV-60-12

LPV-60-15

LPV-60-24

LPV-60-36

LPV-60-48

DC Voltage

5V

12V

15V

24V

36V

48V

Rated Current

8A

5A

4A

2.5A

1.67A

1.25A

Current Range

0-8A

0-5A

0-4A

0-2.5A

0-1.67A

0-1.25A

Rated Power

40W

60W

60W

60W

60W

60W

Ripple & Noise

80mVp-p

120mVp-p

120mVp-p

150mVp-p

150mVp-p

150mVp-p

Voltage Tolerance

±8%

±5%

Line Regulation

±1%

Load Regulation

±6%

±2%

Setup, Rise Time 500ms, 20ms/230VAC   500ms, 20ms/115VAC at full load(for 5-36V) 500ms, 30ms/230VAC   500ms, 30ms/115VAC at full load(for 48V)
Hold Up Time 50ms/230VAC   16ms/115VAC at full load
INPUT

 

Voltage Range

90~264VAC   47-63Hz; 127~370VDC

AC Current 1.2A/115V   1A/230V
Efficiency

76%

83%

83%

86%

86%

86%

Inrush Current Cold Start 60A at 230VAC
Leakage Current 0.25mA/240VAC
PROTECTION  
Over Load 110-150% rated output power
Protection type: Hiccup mode, recovers automatically after fault condition is removed
Over Voltage

5.75-6.75V

13.8-16.2V

17.25-20.25V

27.6-32.4V

41.4-48.6V

55.2-64.8V

Protection type: Shut down o/p voltage, re-power on to recover
ENVIRONMENT  
Working Temp.Humidity -30 ~ +70℃ (Refer to “Derating Curve”)
Storage Temp.Humidity -40℃~+80℃; 10%~95%RH
Temp.Coefficient ±0.03%/℃(0~50℃)
Vibration 10~500Hz,2G 10min,/1cycle,period for 60min,each along X,Y,Z axes
SAFETY  
Withstand Voltage I/P-O/P:3KVAC
Isolation Resistance I/P-O/P>100M Ohms / 500VDC / 25℃ / 70% RH
STANDARD  
Safety Standard UL879(expect for LPV-60-5), UL1310(expect for LPV-60-5), CSA C22.2 No.207-M91(expect for LPV-60-5, LPV-60-48), IP67, IEC60950-1:2005+A2:2013 approved; design refer to TUV EN60950-1
EMC Standard EN61000-4-2,3,4,5,6,8,11,EN55024,light industry level, criteria A
OTHERS  
Dimension 162.5*42.5*32mm(L*W*H)
Weight 0.4kg;32pcs/13.8kg/0.56CUFT
NOTE  
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25℃ of ambient temperature. 2. Ripple & noise are measured at 20MHz of bandwidth by using a 12” twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor. 3. Tolerance: includes set up tolerance, line regulation and load regulation. 4. Derating may not be needed under low input voltage. Please check the static characteristics for more details.

Features

Hot Products

155W Dual Output with Battery Charger (UPS Function) ADD-155 series

155W Dual Output with Battery Charger (UPS Function) ADD-155 series

15W Single Output Industrial DIN Rail Power Supply DR-15 series

15W Single Output Industrial DIN Rail Power Supply DR-15 series

OPIM-0600W-Modified Sine Wave Power Inverter

OPIM-0600W-Modified Sine Wave Power Inverter

120W UPS Function Battery Power Supply SC-120 Series

120W UPS Function Battery Power Supply SC-120 Series

120W Single Output Industrial DIN Rail Power Supply       EDR-120 series

120W Single Output Industrial DIN Rail Power Supply EDR-120 series

16mm Black Button Switch

16mm Black Button Switch

OPIM-0500W- Modified Sine Wave Power Inverter

OPIM-0500W- Modified Sine Wave Power Inverter

LW31-Rotary Switch

LW31-Rotary Switch

360W Single Output Switching Power Supply S-360 series

360W Single Output Switching Power Supply S-360 series

OPIM-2000C Modified Sine Wave Inverter With Charger

OPIM-2000C Modified Sine Wave Inverter With Charger

Contact us

Please feel free to give your inquiry in the form below We will reply you in 24 hours