Proper use of guide rail power supply
Features
Specifications
SPECIFICATIONS | ||||
OUTPUT | ||||
Model | MDR-60-5 | MDR-60-12 | MDR-60-24 | MDR-60-48 |
DC Voltage | 5V | 12V | 24V | 48V |
Rated Current | 10A | 5A | 2.5A | 1.25A |
Current Range | 0-10A | 0-5A | 0-2.5A | 0-1.25A |
Rated Power | 50W | 60W | 60W | 60W |
Ripple & Noise | 80mVp-p | 120mVp-p | 150mVp-p | 200mVp-p |
Voltage Tolerance | ±2% | ±1% | ±1% | ±1% |
Line regulation | ±1.0% | ±1.0% | ±1.0% | ±1.0% |
Load regulation | ±1.0% | ±1.0% | ±1.0% | ±1.0% |
Setup, Rise Time | 500ms,30ms/230VAC 200ms,30ms/115VAC at full load | |||
Hold Up Time | 50ms/230VAC 20ms/115VAC at full load | |||
INPUT | ||||
Voltage Range | 85~264VAC 47~63Hz; 120~370VDC | |||
AC Current | 1.8A/115VAC 1A/ 230VAC | |||
Efficiency | 78% | 86% | 88% | 87% |
Inrush Current | Cold start 30A/115VAC 60A/230VAC | |||
Leakage Current | <1mA/240VAC | |||
PROTECTION | ||||
Over Load | 105%~150% rated output power | |||
Protection type: Constant current limiting, recovers automatically after fault condition is removed | ||||
Over Voltage | 6.25-7.25V | 15.6-18V | 31.2-36V | 57.6-64.8V |
Protection type: Shut down o/p voltage, re-power on to recover | ||||
ENVIRONMENT | ||||
Working Temp., Humidity | -20℃~+70℃; 20%~90% RH non-condensing | |||
Storage Temp., Humidity | -40℃~+85℃; 10%~95%RH | |||
Temp. Coefficient | ±0.03%/℃(0~50℃) | |||
Vibration | 10~500Hz, 2G 10min./1cycle, period for 60min, each along X, Y, Z axes | |||
SAFETY | ||||
Withstand Voltage | I/P-O/P: 3KVAC I/P-FG:2KVAC O/P-FG:0.5KVAC | |||
Isolation Resistance | I/P-O/P, I/P-FG, O/P-F/G: >100M Ohms / 500VDC/25℃/70% RH | |||
STANDARD | ||||
Safety Standard | Design refer to UL508, UL60950-1,TUV EN60950-1,EN50178 | |||
EMC Standard | Design refer to EN55011,EN55022,EN61000-3-2,-3,EN61000-4-2,3,4,5,6,8,11,EN55024,EN61000-6-2,EN61204-3, heavy industry level, criteria A | |||
OTHERS | ||||
Dimension | 40*90*100mm(W*H*D) | |||
Weight | 0.33Kg | |||
Packing | 42pcs/carton/14.8kg/0.82CUFT | |||
NOTE | ||||
1.All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25℃ of ambient temperature. 2.Ripple & noise are measured at 20MHz of bandwidth by using a 12” twisted pair-wire terminated with a 0.1μ & 47μ parallel capacitor. 3.Tolerance: includes set up tolerance, line regulation and load regulation. 4.The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets EMC directives. |