60W Dual Output Switching Power Supply D-60 series
High efficiency, high reliability
Universal AC input /full range
100% full load burn-in test
Protections: Short circuit/ Over load/ Over voltage
LED indicator for power on
Cooling by free air convection
Fixed switching frequency at 54KHz
2 years warranty
Features
Specifications
| SPECIFICATIONS | ||||||
| OUTPUT | ||||||
| Model | D-60A | D-60B | D-60C | |||
| Output number | CH1 | CH2 | CH1 | CH2 | CH1 | CH2 |
| DC Voltage | 5V | 12V | 5V | 24V | 15V | -15V |
| Rated Current | 4A | 3A | 2A | 2A | 2A | 1.5A |
| Current Range | 0.8-4A | 0.3-3A | 0.8-3A | 0.2-2A | 0.5-2A | 0.2-1.5A |
| Rated Power | 56W | 58W | 60W | |||
| Ripple & Noise | 80mVp-p | 100mVp-p | 80mVp-p | 120mVp-p | 100mVp-p | 120mVp-p |
| Voltage Adj. Range | CH1: -5%,+10% | CH1: -5%,+10% | CH1: -5%,+10% | |||
| Voltage Tolerance | ±2% | ±6% | ±3% | ±5% | ±3% | ±5% |
| Setup,Rise,Hold Up Time | 800ms,50ms,10ms/115VAC 300ms,50ms,80ms/230VAC at full load | |||||
| INPUT | ||||||
| Voltage Range | 85~132VAC/170~264VAC selected by switch 47~63Hz; 240~370VDC | |||||
| AC Current | 1.8A/115V 0.9A/230V | |||||
| Efficiency | 74% | 76% | 78% | |||
| Inrush Current | Cold start 25A/115V 50A/230V | |||||
| Leakage Current | <1mA/240VAC | |||||
| PROTECTION | ||||||
| Over Load | 105%~150% rated output power | |||||
| Protection type: Shut down o/p voltage, recovers automatically after fault condition is removed | ||||||
| Over Voltage | CH1: 115%~135% | |||||
| Protection type: hiccup mode, auto-recovery after fault condition is removed | ||||||
| ENVIRONMENT | ||||||
| Working Temp., Humidity | -10℃~+60℃; 20%~90%RH | |||||
| Storage Temp., Humidity | -20℃~+85℃; 10%~95%RH non-condensing | |||||
| Temp. Coefficient | ±0.03%/℃(0~50℃) | |||||
| Vibration | 10~500Hz, 2G 10min./1cycle, period for 60min, each along X, Y, Z axes | |||||
| SAFETY | ||||||
| Withstand Voltage | I/P-O/P: 1.5KVAC I/P-FG: 1.5KVAC O/P-FG: 0.5KVAC | |||||
| Isolation Resistance | I/P-O/P, I/P-FG, O/P-FG: 100M Ohms/500VDC | |||||
| STANDARD | ||||||
| Safety Standard | Design refer to UL1012, UL60950, EN60950 | |||||
| EMC Standard | Design refer to EN55022(CLSPR22),EN61000-3-2,-3, EN61000-4-2,3,4,5,6,8,11; ENV50204, EN55024 | |||||
| OTHERS | ||||||
| Dimension | 159*97*38mm(L*W*H) | |||||
| Weight | 0.55Kg | |||||
| Packing | 45pcs/25.5Kg/1.45CUFT | |||||
| NOTE | ||||||
| 1.All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25℃ of ambient temperature. | ||||||
| 2.Ripple & noise are measured at 20MHz of bandwidth by using a 12” twisted pair-wire terminated with a 0.1μf & 47μf parallel capacitor. | ||||||
| 3.Tolerance: includes set up tolerance, line regulation and load regulation. | ||||||
| 4.The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets EMC directives. | ||||||