60W Dual Output Switching Power Supply D-60 series
High efficiency, high reliability
Universal AC input /full range
100% full load burn-in test
Protections: Short circuit/ Over load/ Over voltage
LED indicator for power on
Cooling by free air convection
Fixed switching frequency at 54KHz
2 years warranty
Features
Specifications
SPECIFICATIONS | ||||||
OUTPUT | ||||||
Model | D-60A | D-60B | D-60C | |||
Output number | CH1 | CH2 | CH1 | CH2 | CH1 | CH2 |
DC Voltage | 5V | 12V | 5V | 24V | 15V | -15V |
Rated Current | 4A | 3A | 2A | 2A | 2A | 1.5A |
Current Range | 0.8-4A | 0.3-3A | 0.8-3A | 0.2-2A | 0.5-2A | 0.2-1.5A |
Rated Power | 56W | 58W | 60W | |||
Ripple & Noise | 80mVp-p | 100mVp-p | 80mVp-p | 120mVp-p | 100mVp-p | 120mVp-p |
Voltage Adj. Range | CH1: -5%,+10% | CH1: -5%,+10% | CH1: -5%,+10% | |||
Voltage Tolerance | ±2% | ±6% | ±3% | ±5% | ±3% | ±5% |
Setup,Rise,Hold Up Time | 800ms,50ms,10ms/115VAC 300ms,50ms,80ms/230VAC at full load | |||||
INPUT | ||||||
Voltage Range | 85~132VAC/170~264VAC selected by switch 47~63Hz; 240~370VDC | |||||
AC Current | 1.8A/115V 0.9A/230V | |||||
Efficiency | 74% | 76% | 78% | |||
Inrush Current | Cold start 25A/115V 50A/230V | |||||
Leakage Current | <1mA/240VAC | |||||
PROTECTION | ||||||
Over Load | 105%~150% rated output power | |||||
Protection type: Shut down o/p voltage, recovers automatically after fault condition is removed | ||||||
Over Voltage | CH1: 115%~135% | |||||
Protection type: hiccup mode, auto-recovery after fault condition is removed | ||||||
ENVIRONMENT | ||||||
Working Temp., Humidity | -10℃~+60℃; 20%~90%RH | |||||
Storage Temp., Humidity | -20℃~+85℃; 10%~95%RH non-condensing | |||||
Temp. Coefficient | ±0.03%/℃(0~50℃) | |||||
Vibration | 10~500Hz, 2G 10min./1cycle, period for 60min, each along X, Y, Z axes | |||||
SAFETY | ||||||
Withstand Voltage | I/P-O/P: 1.5KVAC I/P-FG: 1.5KVAC O/P-FG: 0.5KVAC | |||||
Isolation Resistance | I/P-O/P, I/P-FG, O/P-FG: 100M Ohms/500VDC | |||||
STANDARD | ||||||
Safety Standard | Design refer to UL1012, UL60950, EN60950 | |||||
EMC Standard | Design refer to EN55022(CLSPR22),EN61000-3-2,-3, EN61000-4-2,3,4,5,6,8,11; ENV50204, EN55024 | |||||
OTHERS | ||||||
Dimension | 159*97*38mm(L*W*H) | |||||
Weight | 0.55Kg | |||||
Packing | 45pcs/25.5Kg/1.45CUFT | |||||
NOTE | ||||||
1.All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25℃ of ambient temperature. | ||||||
2.Ripple & noise are measured at 20MHz of bandwidth by using a 12” twisted pair-wire terminated with a 0.1μf & 47μf parallel capacitor. | ||||||
3.Tolerance: includes set up tolerance, line regulation and load regulation. | ||||||
4.The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets EMC directives. |