Features
Specifications
SPECIFICATION | |||||
OUTPUT | |||||
Model | NES-35-5 | NES-35-12 | NES-35-15 | NES-35-24 | NES-35-48 |
DC Voltage | 5V | 12V | 15V | 24V | 48V |
Rated Current | 7A | 3A | 2.4A | 1.5A | 0.8A |
Current Range | 0 ~ 7A | 0 ~ 3A | 0 ~ 2.4A | 0 ~ 1.5A | 0 ~ 0.8A |
Rated Power | 35W | 36W | 36W | 36W | 38.4W |
Ripple & Noise | 80mVp-p | 120mVp-p | 150mVp-p | 200mVp-p | 240mVp-p |
Voltage Adj. Range | 4.75 ~ 5.5V | 10.8 ~ 13.2V | 13.5 ~ 16.5V | 21.6 ~ 26.4V | 43.2 ~ 52.8V |
Voltage Tolerance | ±2.0% | ±1.0% | ±1.0% | ±1.0% | ±1.0% |
Line Regulation | ±0.5% | ±0.5% | ±0.5% | ±0.5% | ±0.5% |
Load Regulation | ±0.5% | ±0.5% | ±0.5% | ±0.5% | ±0.5% |
Setup, Rise Time | 500ms, 30ms/230VAC 1200ms, 30ms/115VAC at full load | ||||
Hold Up Time | 50ms/230VAC 10ms/115VAC at full load | ||||
INPUT | |||||
Voltage Range | 85 ~ 264VAC 120 ~ 370VDC | ||||
Frequency Range | 47 ~ 63Hz | ||||
Efficiency | 78% | 81% | 83% | 85% | 86% |
AC Current | 0.75A/115VAC 0.5 A/230VAC | ||||
Inrush Current | Cold Start 45A | ||||
Leakage Current | <2mA / 240VAC | ||||
PROTECTION | |||||
Over Load | 110 ~ 150% rated output power | ||||
Protection type: Hiccup mode, recovers automatically after fault condition is removed | |||||
Over Voltage | 5.75~6.75V | 13.8~16.2V | 17.25~20.25V | 27.6~32.4V | 55.2~64.8V |
Protection type: Shut down o/p voltage, re-power on to recover | |||||
ENVIRONMENT | |||||
Working Temp. | -20 ~ +60℃ (Refer to “Derating Curve”) | ||||
Working Humidity | 20 ~ 90% RH non-condensing | ||||
Storage Temp., Humidity | -40 ~ +85℃, 10 ~ 95% RH | ||||
Temp. Coefficient | ±0.03%/℃ (0 ~ 45℃) | ||||
Vibration | 10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes | ||||
SAFETY & EMC | |||||
Safety Standards | UL60950-1, CB(IEC60950-1),CCC GB4943 approved | ||||
Withstand Voltage | I/P-O/P:3KVAC I/P-FG:2KVAC O/P-FG:0.5KVAC | ||||
Isolation Resistance | I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25℃ / 70% RH | ||||
EMC Emission | Compliance to EN55022 (CISPR22) Class B, EN61000-3-2,-3 | ||||
EMC Immunity | Compliance to EN61000-4-2, 3, 4, 5, 6, 8,11, EN55024, EN61000-6-1, light industry level, criteria A | ||||
OTHERS | |||||
Dimension | 99*97*36mm (L*W*H) | ||||
Weight | 0.36Kg | ||||
Packing | 45pcs/17.2Kg/0.93CUFT | ||||
NOTE | |||||
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25℃ of ambient temperature. 2. Ripple & noise are measured at 20MHz of bandwidth by using a 12” twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor. 3. Tolerance: includes set up tolerance, line regulation and load regulation. 4. Line regulation is measured from low line to high line at rated load. 5. Load regulation is measured from 0% to 100% rated load. 6. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets EMC directives. |