Features
Specifications
SPECIFICATIONS | ||||||||
OUTPUT | ||||||||
Model | SP-320-5 | SP-320-7.5 | SP-320-12 | SP-320-13.5 | SP-320-15 | SP-320-24 | SP-320-27 | SP-320-48 |
DC Voltage | 5V | 7.5V | 12V | 13.5V | 15V | 24V | 27V | 48V |
Rated Current | 55A | 40A | 25A | 22A | 20A | 13A | 11.7A | 6.7A |
Current Range | 0-55A | 0-40A | 0-25A | 0-22A | 0-20A | 0-13A | 0-11.7A | 0-6.7A |
Rated Power | 275W | 300W | 300W | 297W | 300W | 312W | 315.9W | 321.6W |
Ripple & Noise | 150mVp-p | 150mVp-p | 150mVp-p | 150mVp-p | 150mVp-p | 150mVp-p | 200mVp-p | 240mVp-p |
DC Adjustment Range | ±10% | ±20% | -16%,+10% | ±11% | -10%,+20% | -16%,+10% | -4%,+18% | -15%,+17% |
Voltage Tolerance | ±2% | ±2% | ±1% | ±1% | ±1% | ±1% | ±1% | ±1.0% |
Line Regulation | ±0.5% | ±0.5% | ±0.3% | ±0.3% | ±0.3% | ±0.2% | ±0.2% | ±0.2% |
Load Regulation | ±1% | ±1% | ±0.5% | ±0.5% | ±0.5% | ±0.5% | ±0.5% | ±0.5% |
Setup, Rise, Hold Up Time | 800ms,50ms,16ms/230VAC 2500ms,50ms,16ms/115VAC at full load | |||||||
INPUT | ||||||||
Voltage Range | 88~264VAC 120~370VDC frequency: 47~63 Hz | |||||||
AC Current | 5A/115 VAC 2.5A/230VAC | |||||||
Power Factor | PF>0.95/230VAC,PF>0.98/115VAC at full load | |||||||
Efficiency | 79% | 83% | 86% | 86% | 86% | 87% | 88% | 89% |
Inrush Current | 20A/115VAC 40A/230VAC | |||||||
Leakage Current | <1mA/240VAC | |||||||
PROTECTION | ||||||||
Over Load | 105%-135% rated output power | |||||||
Protection type: Hiccup mode, recovers automatically after fault condition is removed | ||||||||
Over Voltage(V) | 115%~135% | |||||||
Protection type: Shut down o/p voltage, re-power on to recover | ||||||||
Over Temp. | Shut down o/p voltage, recovers automatically after temperature goes down | |||||||
ENVIRONMENT | ||||||||
Working Temp. Humidity | -20℃~+65℃; 20%~90 % RH non-condensing | |||||||
Storage Temp. Humidity | -40℃~+85℃; 10%~95 % RH | |||||||
Temp. Coefficient | ±0.03%/℃(0~50℃) | |||||||
Vibration | 10~500Hz, 2G 10min./1cycle, period for 60min, each along X, Y, Z axes | |||||||
SAFETY | ||||||||
Withstand Voltage | I/P-O/P:3KVAC I/P-FG:2KVAC O/P-FG: 0.5KVAC | |||||||
Isolation Resistance | I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC/25℃/70% RH | |||||||
STANDARD | ||||||||
Safety Standard | Design refer to UL60950-1,TUV EN60950, CCC | |||||||
EMC Standard | Design refer to EN55022,EN61000-3-2,-3,EN61000-4-2,3,4,5,6,8,11;ENV50204,EN55024, light industry level, criteria A | |||||||
OTHERS | ||||||||
Dimension | 215*115*50mm (L*W*H) | |||||||
Weight | 1.1Kg/pc; 12pcs/14kg/0.95CUFT | |||||||
NOTE | 1.All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25℃ of ambient temperature. | |||||||
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12″twisted pair-wire terminated with a 0.1μf & 47μf parallel capacitor. | ||||||||
3. Tolerance: includes set up tolerance, line regulation and load regulation. | ||||||||
4. The power supply is considered a component which will be installed into final equipment. The final equipment must be re-confirmed that it still meets EMC directives. |