Features
Specifications
SPECIFICATIONS | ||||||
OUTPUT | ||||||
Model | T-30A | T-30B | ||||
Output number | CH1 | CH2 | CH3 | CH1 | CH2 | CH3 |
DC Voltage | 5V | 12V | -5V | 5V | 12V | -12V |
Rated Current | 3A | 1A | 0.5A | 3A | 1A | 0.5A |
Current Range | 0.5-3A | 0.1-1A | 0.1-0.5A | 0.5-3A | 0.1-1A | 0.1-0.5A |
Rated Power | 30W | 33W | ||||
Ripple & Noise | 50mVp-p | 100mVp-p | 50mVp-p | 50mVp-p | 100mVp-p | 100mVp-p |
Voltage Adj. Range | CH1: -5%, +10% | CH1: -5%, +10% | ||||
Voltage Tolerance | ±2% | +2%,-6% | +2%,-10% | ±2% | +2%,-6% | ±6% |
Setup, Rise, Hold Up Time | 200ms,100ms,30ms at full load | |||||
INPUT | ||||||
Voltage Range | 85~132VAC/170~264VAC selected by switch 47~63Hz; 40~370VDC | |||||
AC Current | 0.8A/115V 0.45A/230V | |||||
Efficiency | 70% | 72% | ||||
Inrush Current | Cold start 18A/115V 36A/230V | |||||
Leakage Current | <0.5mA/240VAC | |||||
PROTECTION | ||||||
Over Load | 105%~150% | |||||
Protection type: shut down O/P voltage, re-power on to recover | ||||||
ENVIRONMENT | ||||||
Working Temp., Humidity | -10℃~+60℃; 20%~90%RH | |||||
Storage Temp., Humidity | -20℃~+85℃; 10%~95%RH | |||||
Vibration | 10~500Hz, 2G 10min./1cycle, period for 60min, each along X, Y, Z axes | |||||
SAFETY | ||||||
Withstand Voltage | I/P-O/P:1.5KVAC I/P-FG:1.5KVAC O/P-FG: 0.5KVAC | |||||
Isolation Resistance | I/P-O/P, I/P-FG, O/P-FG:100M Ohms/500VDC | |||||
STANDARD | ||||||
Safety Standard | Design refer to UL 1012 | |||||
EMC Standard | Design refer to FCC Part15 J Conduction Class A | |||||
OTHERS | ||||||
Dimension | 129*98*38mm(L*W*H) | |||||
Weight | 0.42Kg | |||||
Packing | 45pcs/13.6Kg/0.86CUFT | |||||
NOTE | ||||||
1.All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25℃ of ambient temperature. 2.Ripple & noise are measured at 20MHz of bandwidth by using a 12” twisted pair-wire terminated with a 0.1μ & 47μ parallel capacitor. 3.Tolerance: includes set up tolerance, line regulation and load regulation |