1. The input voltage of the waterproof switching power supply should be selected according to the design of the circuit. Generally, there are two kinds of input voltage: 220 volts and 110 volts. If you choose improperly, it will damage the switching power supply.2. Do not connect the ground wire and neutral wire end of the output voltage wiring wrongly, and make sure that the grounding is reliable.3. After the switching power supply is installed, it is necessary to conduct a power-on trial operation, check the condition of each part, and ensure that it can be powered on after it is normal.Finally, pay attention to the heat dissipation of the waterproof switching power supply. It is best to install the switching power supply in a position with good air convection conditions, so that the heat can be easily dissipated.200W Single Output WaterproofSwitching Power Supply LDV-200 seriesHigh efficiency, High reliability, Low costProtections: Short circuit/Over load/Over voltage/High temperatureWaterproof grade: IP67Working Frequency: 65 KHzSuitable for LED lighten and moving sign applications.2 years warranty
Note on the use of waterproof power supply
Specifications
SPECIFICATION
OUTPUT
Model
LDV-200-12
LDV-200-24
LDV-200-36
DC Voltage
12V
24V
36V
Rated Current
16.5A
8.3A
5.5A
Current Range
0-16.5A
0-8.3A
0-5.5A
Rated Power
198W
199W
198W
Ripple & Noise
150mVp-p
200mVp-p
200mVp-p
Voltage Tolerance
±1%
±1%
±1%
Inlet Stability
±0.5%
±0.5%
±0.5%
Load Stability
±0.5%
±0.5%
±0.5%
Setup, Rise, Hold Up Time
200ms,20ms,30ms/230VAC
INPUT
Voltage Range
180~264 VAC 47~63Hz;255~373VDC
AC Current
1.5A/230VAC
Efficiency
82%
84%
85%
Inrush Current
Cold-start current 40A/230VAC
PROTECTION
Over Load
105%~135%
Protection:Hiccup mode, recovers automatically after fault condition is removed
Over Voltage
30~32V
42~44V
Protection:Hiccup mode, recovers automatically after fault condition is removed
High Tem.
≥85℃
Protection:cut off the output, recovers automatically after fault condition is removed
ENVIRONMENT
Working Temp., Humidity
-10℃~+60℃,20%~90%RH
Storage Temp., Humidity
-20℃~+85℃, 10%~95%RH
Temp. Coefficient
±0.03%/℃(0-50℃)
Vibration
10-500Hz,2G 10min,/1cycle,Period for 60min,Each axes
SAFETY
Withstand Voltage
I/P-O/P: 3KVAC I/P-FG: 1.5KVAC O/P-FG: 0.5KVAC
Isolation Resistance
I/P-O/P, I/P-FG, O/P-FG: 100M Ohms/500VDC
STANDARD
Safety Standard
EN61347-1 EN61347-2-13 IP67
EMC Standard
EN55015 EN61547 EN61000-3.4 CLASSB
OTHERS
Dimension
215*69*43(L*W*H)
Weight
1.3Kg
NOTE
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
3. Tolerance: includes set up tolerance, line regulation and load regulation.