PRODUCTS DETAILS

1, switching power supply metal shell power supply shell is generally connected with the ground (FG), to be reliably grounded, to ensure safety, can not be mistakenly connected to the shell on the zero line; 2. Before the installation of switching power supply is completed and powered for trial use, please check and proofread the connection on the terminals again, and make sure that the input and output, AC and DC, single-phase and multi-phase, positive and negative, voltage and current values are correct, and can be powered on. 3, for high-power switching power supply, there are generally two or more than two "+" output terminals "-" "output terminals, in fact, they belong to an output electrode, just for the convenience of users wiring, and the multiple terminals respectively in the internal and connected together;4. In order to achieve full heat dissipation, the general switching power supply should be installed in the position of better air convection conditions, or installed on the chassis shell through the shell to transmit the heat outdoors; 5. Switching power supply is tested with resistive load before delivery. If it needs to be used in capacitive or inductive load, it should be explained in the order contract in advance. 6, for double switching power supply output symmetrical load, the preferred symmetric output power supply; 7. For users with grounded switching power supply FG, it is a normal phenomenon to touch the shell or have hemp electric feeling in the output. When floating to the ground, FG has about 110V AC output to the ground, which is determined by the internal structure of the power supply. 8, switching power supply in the factory before 100% full negative aging, the power utilization rate is generally controlled within 80% or lower, can greatly improve the service life of the power supply, the general situation of power supply temperature increases 10℃ capacitor life reduced - half; 9, switching power supply ripple and noise is superposed on the DC output voltage of AC components, generally expressed with millivolt peak;10, for all switching power supply, when the load mutation, there will be a certain response time, during this mutation, the output voltage of the power supply in the instantaneous will have a short overshoot process, and then return to the normal output state, this is the dynamic response;11, once the switch power supply failure, should notify the factory in the fastest way, the factory will be responsible for free maintenance or technical guidance, except for the private dismantling of the power supply.200W Single Output Switching Power Supply LRS-200 series AC input range selectable by switch Withstand 300VAC surge input for 5 second Protections: Short circuit / Overload / Over voltage/ Over temperature Cooling by free air convection LED indicator for power on 100% full load burn-in test High operating temperature up to 70℃ High efficiency, long life and high reliability 2 years warranty

Features

Notes for switching power supply

Specifications

SPECIFICATION  
OUTPUT  
Model LRS-200-3.3 LRS-200-5 LRS-200-12 LRS-200-15 LRS-200-24 LRS-200-36 LRS-200-48
DC Voltage 3.3V 5V 12V 15V 24V 36V 48V
Rated Current 40A 40A 17A 14A 8.8A 5.9A 4.4A
Current Range 0~40A 0~40A 0~17A 0~14A 0~8.8A 0~5.9A 0~4.4A
Rated Power 132W 200W 204W 210W 211.2W 212.4W 211.2W
Ripple & Noise 150mVp-p 150mVp-p 150mVp-p 150mVp-p 150mVp-p 200mVp-p 200mVp-p
Voltage Adj. Range 2.97~3.6V 4.5 ~ 5.5V 10.2~ 13.8V 13.5~18V 21.6~28.8V 32.4~39.6V 43.2~52.8V
Voltage Tolerance ±3.0% ±3.0% ±1.5% ±1.0% ±1.0% ±1.0% ±1.0%
Line Regulation ±0.5% ±0.5% ±0.5% ±0.5% ±0.5% ±0.5% ±0.5%
Load Regulation ±2.5% ±2.0% ±1.0% ±0.5% ±0.5% ±0.5% ±0.5%
Setup, Rise Time 1300ms, 50ms/230VAC   1300ms, 50ms/115VAC at full load
Hold Up Time 16ms/230VAC   12ms/115VAC at full load
INPUT  
Voltage Range 90 ~ 132VAC / 180 ~ 264VAC selected by switch   254 ~ 370VDC (switch on 230VAC)
Frequency Range 47 ~ 63Hz
Efficiency 87% 88% 89.50% 89.50% 90%
AC Current 4A/115VAC  2.2A/230VAC
Inrush Current Cold start 60A/115VAC   60A/230VAC
Leakage Current <2mA / 240VAC
PROTECTION  
Over Load 110 ~ 140% rated output power
Protection type: Hiccup mode, recovers automatically after fault condition is removed
Over Voltage 5.75~6.75V 13.8 ~ 16.2V 18~21V 28.8 ~ 33.6V 41.4~46.8V 55.2~ 64.8V
Protection type: Hiccup mode, recovers automatically after fault condition is removed
Over temperature Hiccup mode, recovers automatically after fault condition is removed
ENVIRONMENT  
Working Temp. -25 ~ +70℃ (Refer to “derating curve”)
Working Humidity 20 ~ 90% RH non-condensing
Storage Temp., Humidity -40 ~ +85℃, 10 ~ 95% RH
Temp. Coefficient ±0.03%/℃ (0 ~ 50℃)
Vibration 10 ~ 500Hz, 5G 10min./1cycle, 60min. each along X, Y, Z axes
SAFETY  
Safety Standards UL60950-1 approved
Withstand Voltage I/P-O/P:3KVAC   I/P-FG:2KVAC   O/P-FG:0.5KVAC
Isolation Resistance I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25℃ / 70% RH
OTHERS  
Dimension 215*115*30mm (L*W*H)
Weight 0.66Kg
Packing 15pcs/carton/10.9kg/0.78CUFT
NOTE  
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25℃ of ambient temperature. 2. Ripple & noise are measured at 20MHz of bandwidth by using a 12” twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor. 3. Tolerance: includes set up tolerance, line regulation and load regulation. 4. Line regulation is measured from low line to high line at rated load. 5. Load regulation is measured from 0% to 100% rated load. 6. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets EMC directives. 7. Length of set up time is measured at cold first start. Turning ON/OFF the power supply very quickly may lead to increase of the set up time.
 

Hot Products

60W Single Output Waterproof Switching Power Supply LDV-60 series

60W Single Output Waterproof Switching Power Supply LDV-60 series

JQ-6030-Scrolling System

JQ-6030-Scrolling System

60W Dual Output Switching Power Supply D-60 series

60W Dual Output Switching Power Supply D-60 series

LW6D-rotary switch 

LW6D-rotary switch 

150W Single Output Switching Power Supply NES-150 series

150W Single Output Switching Power Supply NES-150 series

35W UPS Function Battery Power Supply SC-35 Series

35W UPS Function Battery Power Supply SC-35 Series

60W Single Output Industrial DIN Rail Power Supply DR-60 series

60W Single Output Industrial DIN Rail Power Supply DR-60 series

OPIM-2500W-Modified Sine Wave Power Inverter

OPIM-2500W-Modified Sine Wave Power Inverter

200W Single Output Switching Power Supply LRS-200 series

200W Single Output Switching Power Supply LRS-200 series

120W Single Output UPS function Power Supply  SCP-120 series

120W Single Output UPS function Power Supply SCP-120 series

Contact us

Please feel free to give your inquiry in the form below We will reply you in 24 hours