Features
Specifications
SPECIFICATIONS | |||||||
OUTPUT | |||||||
Model | SP-150-5 | SP-150-7.5 | SP-150-12 | SP-150-13.5 | SP-150-15 | SP-150-24 | SP-150-27 |
DC Voltage | 5V | 7.5V | 12V | 13.5V | 15V | 24V | 27V |
Rated Current | 30A | 20A | 12.5A | 11.2A | 10A | 6.3A | 5.6A |
Current Range | 0-30A | 0-20A | 0-12.5A | 0-11.2A | 0-10A | 0-6.3A | 0-5.6A |
Rated Power | 150W | 150W | 150W | 151.2W | 150W | 150W | 151.2W |
Ripple & Noise | 100mVp-p | 100mVp-p | 100mVp-p | 100mVp-p | 100mVp-p | 150mVp-p | 150mVp-p |
DC Adjustment Range | -5%,+10% | -5%,+10% | -5%,+10% | -5%,+10% | -5%,+10% | -5%,+10% | -5%,+10% |
Voltage Tolerance | ±2% | ±2% | ±2% | ±2% | ±2% | ±1% | ±1% |
Line Regulation | ±0.5% | ±0.5% | ±0.5% | ±0.5% | ±0.5% | ±0.5% | ±0.5% |
Load Regulation | ±1% | ±1% | ±0.5% | ±0.5% | ±0.5% | ±0.5% | ±0.5% |
Setup, Rise, Hold Up Time | 700ms,400ms,20ms at full load | ||||||
INPUT | |||||||
Voltage Range | 85~264 VAC 47-63Hz;120~370VDC | ||||||
AC Current | 2.5A/115 VAC 1.2A/230VAC | ||||||
Power Factor | PF>0.93/230VAC,PF>0.97/115VAC at full load | ||||||
Efficiency | 77.50% | 81% | 84% | 85% | 85% | 85% | |
Inrush Current | Cold start 45A/230VAC | ||||||
Leakage Current | <2mA/240VAC | ||||||
PROTECTION | |||||||
Over Load | 105%-150% rated output power | ||||||
Protection type: Constant current limiting, recovers automatically after fault condition is removed | |||||||
Over Voltage | 110%~135% | ||||||
Protection type: Shut down o/p voltage, re-power on to recover | |||||||
Over Temp. | TSW1(Power transistor) When temp .in 95±5 ℃ shutdown o/p voltage temp . <95±5 ℃O/I auto-recovery. | ||||||
Function | |||||||
Remote Control (option) | CN1:4~10VDC POWER ON, <0~0.8VDC POWER OFF | ||||||
ENVIRONMENT | |||||||
Working Temp. Humidity | -10℃~+55℃; 20%~90% RH non-condensing | ||||||
Storage Temp. Humidity | -20℃~+85℃; 10%~95% RH | ||||||
Temp. Coefficient | ±0.05%/℃(0~50℃) | ||||||
Vibration | 10~500Hz, 2G 10min./1cycle, period for 60min, each along X, Y, Z axes | ||||||
SAFETY | |||||||
Withstand Voltage | I/P-O/P:3KVAC I/P-FG:2KVAC O/P-FG: 0.5KVAC | ||||||
Isolation Resistance | I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC/25℃/70% RH | ||||||
STANDARD | |||||||
Safety Standard | Design refer to UL60950-1,TUV EN60950-1 | ||||||
EMC Standard | Design refer to EN55022,EN61000-3-2,-3,EN61000-4-2,3,4,5,6,8,11;ENV50204,EN55024, light industry level, criteria A | ||||||
OTHERS | |||||||
Dimension | 199*99*50mm(L*W*H) | ||||||
Weight | 0.76Kg;20pcs/16.4kg/1.28CUFT | ||||||
NOTE | 1.All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25℃ of ambient temperature. | ||||||
2.Ripple & noise are measured at 20MHz of bandwidth by using a 12″twisted pair-wire terminated with a 0.1μf & 47μf parallel capacitor. | |||||||
3.Tolerance: includes set up tolerance, line regulation and load regulation. | |||||||
4.The power supply is considered a component which will be installed into final equipment. The final equipment must be re-confirmed that it still meets EMC directives. |